| Geiler & Associates, LLC provides Industrial
Projects with interior & exterior sound isolation, mechanical
noise and vibration control, interior acoustic design, and
other professional services as projects require. We determine
and evaluate equipment noise and vibration levels and can
provide mitigation recommendations. For facilities including
control rooms, meeting rooms or other acoustically sensitive
spaces, we provide recommendations to improve interior room
acoustics and speech intelligibility. We provide on-site environmental
noise testing to evaluate site and/or property line noise
& vibration levels. Geiler & Associates, LLC personnel
have been involved with a broad range of challenging industrial
projects. |
-
| Kerr McGee Gathering Natural Gas Compressor
Station Platteville, Colorado
Provided Exterior Noise Mitigation to meet property line
noise ordinates and residential requirements. Mechanical
System included two CAT 3612 Engines and associated Air
Exchangers.
Client: H. S. Resources
Brighton, Colorado |
Level 3 2200 Alameda
Denver, Colorado
Data Communication Warehouse
Provided Exterior Noise Mitigation to meet property line
noise ordinates, Sound Insulation Design and Mechanical
Noise & Vibration Control. Mechanical Noise & Vibration
Control included Eight 2,000 kW Generator Sets and Transformers.
Client: The Crosby Group, Inc
Littleton, Colorado |
| Pope & Talbot Lumber Mill
Spearfish, South Dakota
Designed an acoustic arbor belt guard to replace an existing
guard. The acoustic guard was designed to mitigate noise
generated by the arbor belts and remove the generated heat
load.
Client: Pope & Talbot Lumber Mill,
Spearfish, South Dakota |
Abiquiu Dam Bypass Project Abiquiu
Dam, New Mexico
Determined expected Noise Levels within the Dam Gate Valve
Bell Chamber and Bifurcation; due to the Operation of a
Constant Flow Bypass running through the Dam Penstock.
Client: Bath Engineering Group
El Paso, Texas |
| @Lightspeed Telecom Hotel
Denver, Colorado
Data Communication Warehouse
Provided Exterior Noise Mitigation to meet property line
noise ordinates. Mechanical System included thirteen 2,000
kW Generator Sets and Transformers.
Client: DLB Associates, Consulting Engineers
Hartford, Connecticut |
Mercy Medical Center
Oshkosh, Wisconsin
Provided Interior Acoustic Design, Sound Insulation Design
and Mechanical Noise & Vibration Control. Sound Insulation
Design included designing for a Helicopter Landing Pad located
above the Maternity Ward. Mechanical Noise & Vibration
Control included mitigating an Emergency Generator Set noise
to meet property line ordinances.
Client: Hammel Green Abrahamson, Inc.
Milwaukee, Wisconsin |
| Relera - Main Street Hosting
San Diego, California
Data Communication Warehouse
Provided Interior Acoustic Design, Sound Isolation Design
and Mechanical Noise & Vibration Control. Mechanical
Noise & Vibration Control included mitigating five 2,000
kW Generator Sets and eight Transformers.
Client: Merrick & Company
Denver, Colorado |
Northwest Biological Science Center
Seattle, Washington
Developed remedial Noise Mitigation recommendations to
reduce Emergency Generator Set Noise down to property line
requirements at nearby Residences.
Client: U.S. Fish and Wildlife Service
Denver, Colorado |
| Relera - Main Street Hosting Denver,
Colorado
Data Communication Warehouse
Provided Interior Acoustic Design, Sound Isolation Design
and Mechanical Noise & Vibration Control. Mechanical
Noise & Vibration Control included five 2,000 kW Generator
Sets and eight Transformers.
Client: Merrick & Company
Denver, Colorado |
|
|
|
|